VS1 ZN63A 3.6 - 40.5kV 50Hz Indoor Vacuum 3 Phase Circuit Breaker with XGN2, GG1A - Product
Place of Origin : Shenzhen,China
Delivery Time : 30 Days
Product Description
VS1 ZN63A 3.6 - 40.5kV 50Hz Indoor Vacuum 3 Phase Circuit Breaker with XGN2, GG1A
3 Phase Circuit Breaker Overview
VS1(ZN63A)seriesvacuumbreakerisofindoorhighvoltageswitchgearsuitablefor24kV.
Three-phasepowersystemwith50Hzfrequencyinordertoprotectandcontrolelectricalappliances,
andespeciallysuitableforfrequentoperationatratedcurrentorincessant
opencircuitduetouniqueadvantagesofvacuumcircuitbreaker.
Springoperatingmechanismandbreakerbodypartsadoptintegrationdesign.
Thankfor
Physical Specification
Other Specification : VS1 ZN63A 3.6 - 40.5kV 50Hz Indoor Vacuum 3 Phase Circuit Breaker With XGN2, GG1A
3 Phase Circuit Breaker Overview
VS1(ZN63A)seriesvacuumbreakerisofindoorhighvoltageswitchgearsuitablefor24kV.
Three-phasepowersystemwith50Hzfrequencyinordertoprotectandcontrolelectricalappliances,
Andespeciallysuitableforfrequentoperationatratedcurrentorincessant
Opencircuitduetouniqueadvantagesofvacuumcircuitbreaker.
Springoperatingmechanismandbreakerbodypartsadoptintegrationdesign.
Thankforthisdesign, Breakernotonlycanbeafixedinstallationunit,
Butalsocanbeawithdraw-ableunitwithaspeciallypushingframework.
FormeettherequirementofXGN2, GG1Acabinet,
Thefixedtypebreakercanbeinstalladditionallyinterlock.
3 Phase Circuit Breaker Expressionmodeofproductmodel
VS1-24/-
RatedshortcircuitbreakingcurrentkA
RatedcurrentA
RatedvoltagekV
3 Phase Circuit Breaker Productreferencestandard
ShallbeinaccordancewithstandardsinGB1984-89AlternatingCurrentHighVoltageBreaker,
JB3855-19963.6~40.5kVIndoorAlternatingCurrentHighVoltageVacuumBreaker,
AndDL403-1999SpecificationforOrderof10~35kVIndoorHighVoltageVacuumBreaker,
AndsubjecttorelativerequirementsinIEC56(87publication).
3 Phase Circuit Breaker Operatingenvironmentcondition
A)Normaloperatingenvironmentcondition
Highesttemperature:+40C
Lowesttemperature:-15C
B)Environmenthumidity
Dailyaveragerelativehumidity:95%
Monthlyaveragerelativehumidity:90%
Dailyaveragesaturatedvaporpressure:2.210-3MPa
Monthlyaveragesaturatedvaporpressure:1.810-3MPa
C)Altitude:below1000marea
D)Earthquakeintensity:nomorethan8degree
E)Theproductshallbeawayfromweep, Fireandexplosion, Chemicalcorrosionandstrenuousvibrationplace.
3 Phase Circuit Breaker Mainspecificationsandtechnicalparameters ( RefertoTab1)
- - - -
NO | Item | Unit | TechnicalDate |
1 | Ratedvoltage | KV | 24 |
2 | Ratedinsulatinglevel | Ratedshor