1000KVA / 8000W load 4A 50hz Outdoor UPS HW9110E for outside communications - Product
Place of Origin : Shenzhen,China
Delivery Time : Within 15-30days After Receiving Your 30% TT Depo
Product Description
1000KVA / 8000W load4A50hz Outdoor UPS HW9110Efor outside communications
Key Features
SORO Outdoor Intelligent High Frequency Online UPS provide continuous pure sine wave AC power supply for outside communications / network equipment.
Double-conversion online design, high temperature resistant, anti-cold, sealing level for IP55; With the wide range of input voltage and frequency of input window (-45% +35% rated voltage and 10% rated frequency), in many remote areas of China after a se
Physical Specification
Other Specification : 1000KVA / 8000W Load4A50hz Outdoor UPS HW9110Efor Outside Communications
Key Features
SORO Outdoor Intelligent High Frequency Online UPS Provide Continuous Pure Sine Wave AC Power Supply For Outside Communications / Network Equipment.
Double-conversion Online Design, High Temperature Resistant, Anti-cold, Sealing Level For IP55; With The Wide Range Of Input Voltage And Frequency Of Input Window (-45% +35% Rated Voltage And 10% Rated Frequency), In Many Remote Areas Of China After A Severe Test Of The Grid.
[][Inner Structure Of Outdoor UPS HW9110E 1-10KVA:]
Applications
This UPS Is Commonly Used In The Corner Of The City, Remote Roads, Mountains, Bad Environment, Such As High Temperature (+50 C) / Low Temperature (-40 C), Severe Dust, Moisture, Rain, Mist Erosion, Very Poor Power Quality (voltage Long-term Higher Than 260V Or Less Than 160V, Frequency Abnormal Change) In The Area.
Technical Specifications Of Outdoor UPS HW9110E Series
- - - -
Model | HW9110E 1-10KVA |
1KVA | 2KVA | 3KVA | 6KVA | 10KVA |
Capacity | 1KVA/800W | 2KVA/1600W | 3KVA/2400W | 6KVA/4800W | 1000KVA/8000W |
Nominal Voltage | 220/230/240VAC |
Nominal Frequency | 50/60HZ |
Input |
Voltage Range | 115295VAC(3VAC) | 176297VAC(3VAC) |
Frequency Range | 50HZ:(4654HZ)60HZ:(56HZ64HZ) |
Power Factor | 0.98 |
Output |
Voltage Precision | 220/230/240X (12%)VAC |
Frequency Precision | 50/60HZ0.05Hz |
Power Factor | 0.7/0.8(optional) |
Wave Distortion | Linear Load 3% Non-linear Load 6% |
Overload Capability | Overload (110% ~ 150%) For 30 Seconds, Then Automatically Transfer To Bypass. When Load Is Normal, It Can Automatically Transfer To Normal Mode. |
Crest Factor | 3:1 |
Transfer Time | 0ms(AC To DC ) |
Battery |
DC Supply Voltage | 36VDC | 96VDC | 96VDC | 240VDC | 24